기타 계통 고장 코드 5322건 · 8 / 54 페이지. 코드를 누르면 의미·관련 제어기·점검 안내를 확인할 수 있습니다.

11E0E9 CAN communication with component 'ENM' is interrupted.CGW05T 11E1E2 11E1E2ASAT01T 11EBEC Internal error 1(PTI2)ECPC01T 11F0EE ECU eActuator 1 Bridge Driver Charge pump supply error - Special InstructionEDCUZ02B 11F1E9 CAN communication with component 'iPDM-B (ECU99)' is interrupted.CGW05T 11F1EE ECU eActuator 2 Bridge Driver Init error - overcurrent timeout 1 - Special InstructionEDCUZ02B 11F2EA Reserved yellow error for K3 - Abnormal Rate of ChangeEDCUZ02B 11F3EA Message Timeout of Rx_Vehc_TSC1_DD_P4 - Abnormal Rate of ChangeEDCUZ02B 11F4E3 Component 'A10d (central axle modulator (CMAX) control unit)' has a short circuit to positSBSP01T 11F4E4 Component 'A10d (central axle modulator (CMAX) control unit)' has a short circuit to grounSBSP01T 11F4EA Incorrect message counter for Rx_Profile_Short_MSG03 - Abnormal Rate of ChangeEDCUZ02B 11F6EE A watchdog fault was detected at component part 'M61 (drive system (eDrive) coolant pump)'TIO01T 11F9E9 CAN communication with control unit 'A3b (Control unit for drive control (eCPC))' is faultSATP01T 11FBE2 Wrong APS/RPS configurationICC501T 11FBE7 Function 'Radome heater' was not activated.RDF03T 11FDEE Ethernet communication with the "Driver assistance system" has a malfunction.CGW05T 12201F Component 'B304 (Tire pressure control system front axle sensor 2, right)' has an electricSTCU02ST 122704 Fault in hardware of component 'A54 (Electric refrigerant compressor (eKMV))'ECPC01T 126D66 There is currently no further information available on this fault code.DCB01T 128E11 There is currently no further information available on this fault code.DCB01T 128E12 There is currently no further information available on this fault code.DCB01T 128E13 There is currently no further information available on this fault code.DCB01T 128E63 There is currently no further information available on this fault code.DCB01T 128E66 There is currently no further information available on this fault code.DCB01T 128E72 There is currently no further information available on this fault code.DCB01T 128F11 There is currently no further information available on this fault code.DCB01T 128F12 There is currently no further information available on this fault code.DCB01T 128F73 There is currently no further information available on this fault code.DCB01T 12E0E9 CAN communication with component '18U05 (Ancillaries power inverter API1 control unit)' isCGW05T 12E0FF PLC Powerline Communications Signal faultEVCC101T 12E1E9 12E1E9ASAT01T 12EBEC Internal error 2(PTI1)ECPC01T 12F1E9 CAN communication with component 'DCDC-LVA (ECU100)' is interrupted.CGW05T 12F2EA Reserved yellow error for K3 - Abnormal Rate of ChangeEDCUZ02B 12F3EA If the message is not received within a set time, this error is raised. - Abnormal Rate ofEDCUZ02B 12F4E3 Component 'A10d (central axle modulator (CMAX) control unit)' has a short circuit to positSBSP01T 12F4E4 Component 'A10d (central axle modulator (CMAX) control unit)' has a short circuit to grounSBSP01T 12F4EA Incorrect CRC message value of Rx_Profile_Short_Msg03 - Abnormal Rate of ChangeEDCUZ02B 12F6F3 CAN timeout error while communicating with the component 'M61 (drive system (eDrive) coolaTIO01T 12F9E9 CAN communication with control unit 'A7 (Advanced signal acquisition and actuation moduleSATP01T 12FBE9 E2E monitoring of signal group Frame SG_APS_E1_PktICC501T 12FDEE Ethernet communication 'Connectivity' has a malfunction.CGW05T 130702 The signal of component 'B66 (Steering wheel angle sensor (SAS))' is implausible.SAS03T 13201F Signal 'Tire pressure control system' is faulty or not available.STCU02ST 13B544 The vehicle authenticity certificate was not found or is invalid due to data memory failurDCB01T 13B744 The electricity contract certificate was not found or is invalid due to data memory failurDCB01T 13B800 The automatic locking of the charging cable to the charging station has a malfunction.DCB01T 13BC83 The signature of the data transmitted by the charging station is invalid.DCB01T 13CC97 The charging process was aborted by the charging station.DCB01T 13CCFA There is currently no further information available on this fault code.DCB01T 13CCFB There is currently no further information available on this fault code.DCB01T 13CCFC There is currently no further information available on this fault code.DCB01T 13CCFD There is currently no further information available on this fault code.DCB01T 13CD04 Communication between the control unit 'T6 (DC charge-connection unit)' and the charging sDCB01T 13CD63 There is currently no further information available on this fault code.DCB01T 13CD8F Communication between the control unit 'T6 (DC charge-connection unit)' and the charging sDCB01T 13D056 The power supply unit does not support the protocol version of the Powerline CommunicationDCB01T 13D392 The contactor of the charging station was not opened or closed.DCB01T 13D59A The specified time until the start of the charging process was exceeded.DCB01T 13E0E9 CAN communication with component '18U06 (Additional DC/AC converter (API2))' is interrupteCGW05T 13E0FF PLC Powerline Communications Signal faultEVCC101T 13E1E2 13E1E2ASAT01T 13E800 The lock for the charging cable is jammed open.DCB01T 13E900 The lock for the charging cable is jammed closed.DCB01T 13EBEC Internal error 2(PTI2)ECPC01T 13EC44 The master certificate for communication with the power supply unit has an internal fault.DCB01T 13EE81 The charging station certificate is invalid.DCB01T 13EEFA There is currently no further information available on this fault code.DCB01T 13F1E9 CAN communication with component '18U06 (Ancillaries power inverter API2 control unit)' isCGW05T 13F1EE ECU eActuator 2 Bridge Driver Init error - overcurrent result - Special InstructionEDCUZ02B 13F2EA Reserved yellow error for K3 - Abnormal Rate of ChangeEDCUZ02B 13F4E3 Component 'A10d (central axle modulator (CMAX) control unit)' has a short circuit to positSBSP01T 13F4E4 Component 'A10d (central axle modulator (CMAX) control unit)' has a short circuit to grounSBSP01T 13F4E5 Component 'A10d (central axle modulator (CMAX) control unit)' has an open circuit.SBSP01T 13F4EA Message Timeout of Rx_Segment_MSG01 - Abnormal Rate of ChangeEDCUZ02B 13F4F3 LIN timeout error while communicating with component 'B801 (Heat exchanger pressure sensorTIO01T 13F5EF The voltage value of component 'B702 (Rear axle temperature sensor)' is outside the validETCM02T 13F5F1 The voltage value of component 'B702 (Rear axle temperature sensor)' is outside the validETCM02T 13F6E7 The component 'M61 (drive system (eDrive) coolant pump)' is mechanically blocked.TIO01T 13F9E9 CAN communication with control unit 'A10d (central axle modulator (CMAX) control unit)' isSATP01T 13FBE9 E2E monitoring of signal group Frame SG_EAPU_C02_PktICC501T 13FD1C The requested target voltage by the vehicle is outside of the limits of the charging statiDCB01T 13FDEE Ethernet communication 'ETH Mirror' has a malfunction.CGW05T 13FFE9 CAN communication with component 'A35 (Tire pressure monitor (TPM) control unit)' is interCGW05T 142704 Inadequate or absent cooling of cooling circuit (High-voltage battery)ECPC01T 145481 The received certificate from the charging station is expired.DCB01T 145581 The certifying authority for the master certificate of the charging station certificate isDCB01T 145608 The secure connection was aborted by the charging station.DCB01T 145800 The charging station reports an insulation fault.DCB01T 14E0E9 CAN communication with component '18U07 (Ancillaries power inverter API3 control unit)' isCGW05T 14E1ED 14E1EDASAT01T 14EBE0 Motor speed too high (PTI1)ECPC01T 14F0E2 The map data are not compatible with the navigation software.CTP02T 14F1E9 CAN communication with component 'DCDC-LVC (ECU102)' is interrupted.CGW05T 14F2EA Reserved yellow error for K3 - Abnormal Rate of ChangeEDCUZ02B 14F4E3 Component 'A10d (central axle modulator (CMAX) control unit)' has a short circuit to positSBSP01T 14F4E4 Component 'A10d (central axle modulator (CMAX) control unit)' has a short circuit to grounSBSP01T 14F4E5 Component 'A10d (central axle modulator (CMAX) control unit)' has an open circuit.SBSP01T 14F4EA Incorrect message counter for Rx_Segment_Msg01 - Abnormal Rate of ChangeEDCUZ02B 14F4F3 Multiprotocol communication has a malfunction.TIO01T
전화 카톡
길찾기 내차량