KO EN 로그인 · 회원가입 마이페이지 카톡상담 054-286-3838
MERCEDES-BENZ TRUCKS · FAULT CODES

벤츠 트럭 xmc01t 폴트코드 목록

xmc01t 계통 고장 코드 100건. 코드를 누르면 의미·관련 제어기·점검 안내를 확인할 수 있습니다.

00F0E5 Pin A22.X2.52/2 at control unit 'A22 (SAM with additional functions (XMC))' has an open circuit.XMC01T 02F0E2 DTC_PlausiCheck_RDL_BCAN_vs_PinXMC01T 040A00 The measurement value of component 'B75 (1st front axle temperature sensor)' is above the measuring range.XMC01T 040A01 The measurement value of component 'B75 (1st front axle temperature sensor)' is below the measuring range.XMC01T 0CF1E3 Pin A22.X2.52/29 at component 'A22 (SAM with additional functions (XMC))' has a short circuit to positive.XMC01T 0DF1E3 Pin A22.X2.52/42 at component 'A22 (SAM with additional functions (XMC))' has a short circuit to positive.XMC01T 0E0A00 The measurement value of component 'B80 (Transfer case temperature sensor)' is above the measuring range.XMC01T 0E0A01 The measurement value of component 'B80 (Transfer case temperature sensor)' is below the measuring range.XMC01T 0EF1E3 Pin A22.X2.52/43 at component 'A22 (SAM with additional functions (XMC))' has a short circuit to positive.XMC01T 0FF1E3 Pin A22.X3.21/20 at component 'A22 (SAM with additional functions (XMC))' has a short circuit to positive.XMC01T 0FF1E4 Pin A22.X3.21/20 at component 'A22 (SAM with additional functions (XMC))' has a short circuit to ground.XMC01T 0FF1E5 Pin A22.X3.21/20 at control unit 'A22 (SAM with additional functions (XMC))' has an open circuit.XMC01T 10F1E3 Pin A22.X3.21/14 at component 'A22 (SAM with additional functions (XMC))' has a short circuit to positive.XMC01T 10F1E4 Pin A22.X3.21/14 at component 'A22 (SAM with additional functions (XMC))' has a short circuit to ground.XMC01T 10F1E5 Pin A22.X3.21/14 at control unit 'A22 (SAM with additional functions (XMC))' has an open circuit.XMC01T 11F1E3 Pin A22.X2.52/15 at component 'A22 (SAM with additional functions (XMC))' has a short circuit to positive.XMC01T 11F1E4 Pin A22.X2.52/15 at component 'A22 (SAM with additional functions (XMC))' has a short circuit to ground.XMC01T 11F1E5 Pin A22.X2.52/15 at control unit 'A22 (SAM with additional functions (XMC))' has an open circuit.XMC01T 12F1E3 Pin A22.X3.21/2 at component 'A22 (SAM with additional functions (XMC))' has a short circuit to positive.XMC01T 12F1E4 Pin A22.X3.21/2 at component 'A22 (SAM with additional functions (XMC))' has a short circuit to ground.XMC01T 12F1E5 Pin A22.X3.21/2 at control unit 'A22 (SAM with additional functions (XMC))' has an open circuit.XMC01T 13F1E5 Pin A22.X2.52/16 at control unit 'A22 (SAM with additional functions (XMC))' has an open circuit.XMC01T 16F1E2 The signal output at pin {0} is implausible.XMC01T 17F1E2 The signal output at pin {0} is implausible.XMC01T 18F1E2 The signal output at pin {0} is implausible.XMC01T 19F1E2 The signal output at pin {0} is implausible.XMC01T 1AF1E2 The signal output at pin {0} is implausible.XMC01T 1B0A03 Pin A22.X1.40/16 at component 'A22 (SAM with additional functions (XMC))' has a short circuit to positive.XMC01T 1B0A04 Pin A22.X1.40/16 at component 'A22 (SAM with additional functions (XMC))' has a short circuit to ground.XMC01T 1BF1E2 The signal output at pin {0} is implausible.XMC01T 1F0A03 Pin A22.X1.40/24 at component 'A22 (SAM with additional functions (XMC))' has a short circuit to positive.XMC01T 1F0A04 Pin A22.X1.40/24 at component 'A22 (SAM with additional functions (XMC))' has a short circuit to ground.XMC01T 20F1E2 The signal output at pin {0} is implausible.XMC01T 21F1E2 The signal output at pin {0} is implausible.XMC01T 22F1E2 The signal output at pin {0} is implausible.XMC01T 23F1E2 The signal output at pin {0} is implausible.XMC01T 24F1E2 The signal output at pin {0} is implausible.XMC01T 25F1E2 The signal output at pin {0} is implausible.XMC01T 26F1E2 The signal output at pin {0} is implausible.XMC01T 27F1E2 The signal output at pin {0} is implausible.XMC01T 28F1E2 The signal output at pin {0} is implausible.XMC01T 29F1E2 The signal output at pin {0} is implausible.XMC01T 2AF1E2 The signal output at pin {0} is implausible.XMC01T 2BF1E2 The signal output at pin {0} is implausible.XMC01T 2CF1E1 2CF1E1XMC01T 2DF1E1 2DF1E1XMC01T 2EF1E3 Pin A22.X2.52/36 at component 'A22 (SAM with additional functions (XMC))' has a short circuit to positive.XMC01T 2EF1E4 Pin A22.X2.52/36 at component 'A22 (SAM with additional functions (XMC))' has a short circuit to ground.XMC01T 2FF1E0 The measurement value of component '{0}' is above the measuring range.XMC01T 2FF1E1 The measurement value of component '{0}' is below the measuring range.XMC01T 2FF1ED 2FF1EDXMC01T 35F1E4 Pin A22.X2.52/45 at component 'A22 (SAM with additional functions (XMC))' has a short circuit to ground.XMC01T 36F1E3 Pin A22.X2.52/47 at component 'A22 (SAM with additional functions (XMC))' has a short circuit to positive.XMC01T 36F1E4 Pin A22.X2.52/47 at component 'A22 (SAM with additional functions (XMC))' has a short circuit to ground.XMC01T 37F1E0 The measurement value of component 'B99 (Travel sensor for on-road and off-road gears)' is above the measuring range.XMC01T 37F1E1 The measurement value of component 'B99 (Travel sensor for on-road and off-road gears)' is below the measuring range.XMC01T 38F1E0 The measurement value of component 'B98 (Interaxle differential lock travel sensor)' is above the measuring range.XMC01T 38F1E1 The measurement value of component 'B98 (Interaxle differential lock travel sensor)' is below the measuring range.XMC01T 3DF1E3 Pin A22.X2.52/50 at component 'A22 (SAM with additional functions (XMC))' has a short circuit to positive.XMC01T 3DF1E4 Pin A22.X2.52/50 at component 'A22 (SAM with additional functions (XMC))' has a short circuit to ground.XMC01T 3EF1E3 Pin A22.X2.52/51 at component 'A22 (SAM with additional functions (XMC))' has a short circuit to positive.XMC01T 3EF1E4 Pin A22.X2.52/51 at component 'A22 (SAM with additional functions (XMC))' has a short circuit to ground.XMC01T 3FF1E3 Pin A22.X2.52/49 at component 'A22 (SAM with additional functions (XMC))' has a short circuit to positive.XMC01T 3FF1E4 Pin A22.X2.52/49 at component 'A22 (SAM with additional functions (XMC))' has a short circuit to ground.XMC01T 41F1E5 Pin A22.X2.52/7 at control unit 'A22 (SAM with additional functions (XMC))' has an open circuit.XMC01T 42F1E3 Pin A22.X2.52/9 at component 'A22 (SAM with additional functions (XMC))' has a short circuit to positive.XMC01T 45F1E2 45F1E2XMC01T 46F1E2 46F1E2XMC01T 47F1E2 47F1E2XMC01T 4AF1E2 4AF1E2XMC01T 4EF1E2 4EF1E2XMC01T A2F5E5 Pin A22.X2.52/10 at control unit 'A22 (SAM with additional functions (XMC))' has an open circuit.XMC01T A4EFE0 The fault code is not relevant in this vehicle.XMC01T A4EFE1 The fault code is not relevant in this vehicle.XMC01T A5EFE0 The fault code is not relevant in this vehicle.XMC01T A5EFE1 The fault code is not relevant in this vehicle.XMC01T C7F7EC DTC_XMC_Charge_Pump_FailureXMC01T DFFFFF DFFFFFXMC01T E0FFFF E0FFFFXMC01T E1FFFF E1FFFFXMC01T E2FFFF E2FFFFXMC01T E3FFFF E3FFFFXMC01T E4FFFF E4FFFFXMC01T E5FFFF E5FFFFXMC01T E6FFFF E6FFFFXMC01T E7FFFF E7FFFFXMC01T EAFFE6 Pin A22.X2.52/41 at control unit 'A22 (SAM with additional functions (XMC))' has an open circuit.XMC01T F1FFE3 Pin A22.X1.40/20 at component 'A22 (SAM with additional functions (XMC))' has a short circuit to positive.XMC01T F1FFE4 Pin A22.X1.40/20 at component 'A22 (SAM with additional functions (XMC))' has a short circuit to ground.XMC01T F1FFE5 Pin A22.X1.40/20 at control unit 'A22 (SAM with additional functions (XMC))' has an open circuit.XMC01T FAFFE4 Pin A22.X1.40/37 at component 'A22 (SAM with additional functions (XMC))' has a short circuit to ground.XMC01T FAFFE5 Pin A22.X1.40/37 at control unit 'A22 (SAM with additional functions (XMC))' has an open circuit.XMC01T FC0903 Pin A22.X2.52/4 at component 'A22 (SAM with additional functions (XMC))' has a short circuit to positive.XMC01T FC0904 Pin A22.X2.52/4 at component 'A22 (SAM with additional functions (XMC))' has a short circuit to ground.XMC01T FD0903 Pin A22.X2.52/19 at component 'A22 (SAM with additional functions (XMC))' has a short circuit to positive.XMC01T FD0904 Pin A22.X2.52/19 at component 'A22 (SAM with additional functions (XMC))' has a short circuit to ground.XMC01T FD0905 Pin A22.X2.52/19 at control unit 'A22 (SAM with additional functions (XMC))' has an open circuit.XMC01T FEFFE3 CAN 버스(차체 제조사 CAN 버스) 통신에 오작동이 있습니다.XMC01T FEFFE4 Communication on the CAN bus (Body manufacturer CAN bus) has a malfunction.XMC01T FFFFE4 FFFFE4XMC01T
전화 카톡
길찾기 내차량